Taipei Medical University

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Chen CF
------>authors3_c=???
------>paper_class1=1
------>Impact_Factor=None
------>paper_class3=1
------>paper_class2=1
------>vol=1
------>confirm_bywho=hychiou
------>insert_bywho=clifchen
------>Jurnal_Rank=None
------>authors4_c=
------>comm_author=
------>patent_EDate=None
------>authors5_c=
------>publish_day=1
------>paper_class2Letter=None
------>page2=40
------>medlineContent=
------>unit=E0108
------>insert_date=20080324
------>iam=1
------>update_date=None
------>author=???
------>change_event=4
------>ISSN=
------>authors_c=???
------>score=38
------>journal_name=??????
------>paper_name=IOM??????????????????
------>confirm_date=20080324
------>tch_id=089007
------>pmid=19904652
------>page1=32
------>fullAbstract=Concurrent samples were collected with Andersen and IOM foam samplers to determine whether if the IOM foam sampler can be applied to collect culturable microorganisms. Two different kinds of aerosols were studied: peat dust in a power plant and mist from coolant fluid aerosolized during grinding of blades and rollers in a paper mill. In the power plant, the concentrations of fungi were 2-3 times higher in the IOM samples than in the Andersen samples. However, more fungal genera were identified in the latter case. The methods yielded similar concentrations of bacteria and actinobacteria in the power plant. On the other hand, the performance of the IOM foam sampler was very poor in the paper mill, where stress-sensitive gram-negative bacteria dominated; low concentration of bacteria was detected in only one IOM sample even though the concentration of bacteria often exceeded even the upper detection limit in the Andersen impactor samples. It could be concluded that the IOM foam sampler performs quite well for collecting inhalable fungi and actinobacteria. However, the Andersen sampler provides better information on fungal genera and concentrations of gram-negative bacteria. Personal sampling with the IOM foam sampler provided an important benefit in the power plant, where the concentration ratio of personal to stationary samples was much higher for bacteria than for inhalable or respirable dust.
------>tmu_sno=None
------>sno=17356
------>authors2=Tzeng PC
------>authors3=Chiu WT
------>authors4=
------>authors5=
------>authors6=
------>authors6_c=
------>authors=Chen CF
------>delete_flag=0
------>SCI_JNo=None
------>authors2_c=???
------>publish_area=0
------>updateTitle=The suitability of the IOM foam sampler for bioaerosol sampling in Occupational Environments.
------>language=1
------>check_flag=None
------>submit_date=None
------>country=None
------>no=4
------>patent_SDate=None
------>update_bywho=None
------>publish_year=2007
------>submit_flag=None
------>publish_month=7
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z