Taipei Medical University

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Lu CC
------>authors3_c=
------>paper_class1=1
------>Impact_Factor=None
------>paper_class3=1
------>paper_class2=1
------>vol=22
------>confirm_bywho=chlin
------>insert_bywho=rmchen
------>Jurnal_Rank=None
------>authors4_c=
------>comm_author=
------>patent_EDate=None
------>authors5_c=
------>publish_day=1
------>paper_class2Letter=None
------>page2=12
------>medlineContent=
------>unit=E1300
------>insert_date=20080418
------>iam=4
------>update_date=None
------>author=???
------>change_event=4
------>ISSN=
------>authors_c=
------>score=500
------>journal_name=Journal of Anesthesia
------>paper_name=The effect of heat-moisture exchanger and closed-circuit technique on airway climate during desflurane anesthesia
------>confirm_date=20081118
------>tch_id=088008
------>pmid=18306007
------>page1=7
------>fullAbstract=PURPOSE: We assessed whether closed-circuit anesthesia (CCA) could provide a more favorable airway climate than semi-closed anesthesia (SCA), and we also determined the beneficial effect of heat moisture exchangers (HMEs) on the preservation of airway climate during desflurane anesthesia. METHODS: Forty patients scheduled for colorectal surgery (n = 10 for each group) were randomized to receive a fresh gas flow of 250 or 3000 ml.min(-1) with or without HMEs. Anesthesia was maintained by adjusting the inspired concentration of 6% desflurane. Absolute moisture and temperature of inspired gases were measured as the baseline value first at 5 min after tracheal intubation, and then at 10, 20, 45, 60, 90, and 120 min after the induction of anesthesia. RESULTS: At 120 min, the inspiratory humidity and temperature were higher in CCA than in SCA. The HME led to major improvements of the humidity (from 22.1 to 35.7 mg H(2)O.l(-1)) and temperature (from 23.6 degrees C to 31.5 degrees C) of anesthetic gases in the CCA group. CONCLUSION: CCA was much more advantageous than SCA for maintaining the patient~s airway climate during the 2-h study. The beneficial effect of HME on the airway climate should be emphasized, especially in patients undergoing general anesthesia.
------>tmu_sno=None
------>sno=17631
------>authors2=Ho ST
------>authors3=Liaw WJ
------>authors4=Chen RM
------>authors5=Chen TL
------>authors6=Lin CY
------>authors6_c=
------>authors=Lu CC
------>delete_flag=0
------>SCI_JNo=None
------>authors2_c=
------>publish_area=0
------>updateTitle=The effect of heat-moisture exchanger and closed-circuit technique on airway climate during desflurane anesthesia.
------>language=2
------>check_flag=None
------>submit_date=None
------>country=NULL
------>no=1
------>patent_SDate=None
------>update_bywho=None
------>publish_year=2008
------>submit_flag=None
------>publish_month=4
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z