Taipei Medical University

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Wang YP, Tu PY, Cheung YF, Chen TL, Lin SY, Chao CC
------>authors3_c=None
------>paper_class1=1
------>Impact_Factor=None
------>paper_class3=1
------>paper_class2=1
------>vol=27
------>confirm_bywho=tlc
------>insert_bywho=tlc
------>Jurnal_Rank=None
------>authors4_c=None
------>comm_author=
------>patent_EDate=None
------>authors5_c=None
------>publish_day=None
------>paper_class2Letter=None
------>page2=42
------>medlineContent=
------>unit=E0121
------>insert_date=20000607
------>iam=4
------>update_date=
------>author=???
------>change_event=5
------>ISSN=None
------>authors_c=None
------>score=500
------>journal_name=Acta Anaesthesiologica Sinica
------>paper_name=Evaluation of microleakage due to cuffs of endotracheal tubes during positive end-expiratory pressure ventilation.
------>confirm_date=20020401
------>tch_id=087025
------>pmid=2657303
------>page1=39
------>fullAbstract=Mallinkrodt tubes (internal diameter 8.0 mm) with high residual volume and low pressure cuffs were used to evaluate the influence of positive end-expiratory pressure (PEEP) on leakage from cuffed endotracheal tubes. A thin smooth epidural catheter (Portex) was placed immediately above the cuff to monitor visually whether methylene blue dye solution (2-3 ml) passed through the cuff and stained the trachea. One hundred male patients undergoing elective orthopedic surgical procedures were randomly divided into five groups: a control group and groups using 2.5, 5.0, 7.5, and 10 cm H2O of PEEP during nitrous oxide-oxygen-isoflurane anesthesia. The cuff pressure was set to 25 cm H2O in each group. The cuff pressure was recalibrated and evidence of staining below the cuff was sought with a fiberscope every twenty minutes for a total of three times. Leakage increased with PEEP level but the amount was not statistically significant and the difference between groups was not significant.
------>tmu_sno=None
------>sno=1839
------>authors2=None
------>authors3=None
------>authors4=None
------>authors5=None
------>authors6=None
------>authors6_c=None
------>authors=Wang YP, Tu PY, Cheung YF, Chen TL, Lin SY, Chao CC
------>delete_flag=0
------>SCI_JNo=None
------>authors2_c=None
------>publish_area=None
------>updateTitle=Evaluation of microleakage due to cuffs of endotracheal tubes during positive end-expiratory pressure ventilation.
------>language=2
------>check_flag=
------>submit_date=
------>country=None
------>no=
------>patent_SDate=None
------>update_bywho=
------>publish_year=1989
------>submit_flag=
------>publish_month=None
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z