Huang Chun-Yao |
------>authors3_c= ------>paper_class1=1 ------>Impact_Factor=None ------>paper_class3=1 ------>paper_class2=3 ------>vol= ------>confirm_bywho=ncchang ------>insert_bywho=ncchang ------>Jurnal_Rank=None ------>authors4_c= ------>comm_author=1 ------>patent_EDate=None ------>authors5_c= ------>publish_day=1 ------>paper_class2Letter=None ------>page2= ------>medlineContent= ------>unit=E0109 ------>insert_date=20080613 ------>iam=3 ------>update_date=None ------>author=??? ------>change_event=4 ------>ISSN= ------>authors_c= ------>score=68 ------>journal_name=J Taiwan Soc Echocardiogr, June 2008, 2(2): 75-82. ------>paper_name=Real-time 3-dimensional echocardiography in evaluating the left ventricle. ------>confirm_date=20080613 ------>tch_id=075008 ------>pmid=17261386 ------>page1= ------>fullAbstract=Echocardiographic follow-up of left ventricular (LV) volumes is difficult because of the test-retest variation of 2-dimensional echocardiography (2DE). We investigated whether the accuracy and reproducibility of real-time 3-dimensional echocardiography (RT3DE) would make this modality more feasible for serial follow-up of LV measurements. We performed 2DE and RT3DE and cardiac magnetic resonance imaging (MRI) in 50 patients with previous infarction and varying degrees of LV function (44 men; 61 +/- 11 years of age) at baseline and after 1-year follow-up. Images were obtained during breath-hold and measurements of LV volumes and ejection fraction were made offline. Over follow-up, end-diastolic volume decreased from 192 +/- 53 to 187 +/- 60 ml (p <0.01), end-systolic volume decreased from 104 +/- 51 to 95 +/- 53 ml (p <0.01), and ejection fraction increased from 48 +/- 12% to 51 +/- 12% (p <0.01). MRI showed that LV mass shrank from 183 +/- 39 to 182 +/- 37 g (p <0.01). The correlation between change in RT3DE and change in MRI was greater than the correlations of 2DE with MRI for measurement of end-diastolic volume (r = 0.47 vs 0.02, p <0.01), end-systolic volume (r = 0.44 vs 0.17, p <0.01), and ejection fraction (r = 0.58 vs -0.03, p <0.01). The change in end-diastolic volume between baseline and follow-up with RT3DE (-4 +/- 20, p <0.01) was similar to that with MRI but was unrecognized by 2DE (4 +/- 19, p = 0.09). There was good test-retest and inter- and intraobserver correlation within RT3DE for volumes, ejection fraction, and mass. In conclusion, if sequential measurement of LV volumes is used to guide management decisions, 3DE appears preferable to 2DE. ------>tmu_sno=None ------>sno=18699 ------>authors2=Lin Mei-Shu ------>authors3=Chang Nen-Chung ------>authors4= ------>authors5= ------>authors6= ------>authors6_c= ------>authors=Huang Chun-Yao ------>delete_flag=0 ------>SCI_JNo=None ------>authors2_c= ------>publish_area=0 ------>updateTitle=Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction. ------>language=1 ------>check_flag=None ------>submit_date=None ------>country=NULL ------>no= ------>patent_SDate=None ------>update_bywho=None ------>publish_year=2008 ------>submit_flag=None ------>publish_month=6 |