Taipei Medical University

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Huang Chun-Yao
------>authors3_c=
------>paper_class1=1
------>Impact_Factor=None
------>paper_class3=1
------>paper_class2=3
------>vol=
------>confirm_bywho=ncchang
------>insert_bywho=ncchang
------>Jurnal_Rank=None
------>authors4_c=
------>comm_author=1
------>patent_EDate=None
------>authors5_c=
------>publish_day=1
------>paper_class2Letter=None
------>page2=
------>medlineContent=
------>unit=E0109
------>insert_date=20080613
------>iam=3
------>update_date=None
------>author=???
------>change_event=4
------>ISSN=
------>authors_c=
------>score=68
------>journal_name=J Taiwan Soc Echocardiogr, June 2008, 2(2): 75-82.
------>paper_name=Real-time 3-dimensional echocardiography in evaluating the left ventricle.
------>confirm_date=20080613
------>tch_id=075008
------>pmid=17261386
------>page1=
------>fullAbstract=Echocardiographic follow-up of left ventricular (LV) volumes is difficult because of the test-retest variation of 2-dimensional echocardiography (2DE). We investigated whether the accuracy and reproducibility of real-time 3-dimensional echocardiography (RT3DE) would make this modality more feasible for serial follow-up of LV measurements. We performed 2DE and RT3DE and cardiac magnetic resonance imaging (MRI) in 50 patients with previous infarction and varying degrees of LV function (44 men; 61 +/- 11 years of age) at baseline and after 1-year follow-up. Images were obtained during breath-hold and measurements of LV volumes and ejection fraction were made offline. Over follow-up, end-diastolic volume decreased from 192 +/- 53 to 187 +/- 60 ml (p <0.01), end-systolic volume decreased from 104 +/- 51 to 95 +/- 53 ml (p <0.01), and ejection fraction increased from 48 +/- 12% to 51 +/- 12% (p <0.01). MRI showed that LV mass shrank from 183 +/- 39 to 182 +/- 37 g (p <0.01). The correlation between change in RT3DE and change in MRI was greater than the correlations of 2DE with MRI for measurement of end-diastolic volume (r = 0.47 vs 0.02, p <0.01), end-systolic volume (r = 0.44 vs 0.17, p <0.01), and ejection fraction (r = 0.58 vs -0.03, p <0.01). The change in end-diastolic volume between baseline and follow-up with RT3DE (-4 +/- 20, p <0.01) was similar to that with MRI but was unrecognized by 2DE (4 +/- 19, p = 0.09). There was good test-retest and inter- and intraobserver correlation within RT3DE for volumes, ejection fraction, and mass. In conclusion, if sequential measurement of LV volumes is used to guide management decisions, 3DE appears preferable to 2DE.
------>tmu_sno=None
------>sno=18699
------>authors2=Lin Mei-Shu
------>authors3=Chang Nen-Chung
------>authors4=
------>authors5=
------>authors6=
------>authors6_c=
------>authors=Huang Chun-Yao
------>delete_flag=0
------>SCI_JNo=None
------>authors2_c=
------>publish_area=0
------>updateTitle=Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction.
------>language=1
------>check_flag=None
------>submit_date=None
------>country=NULL
------>no=
------>patent_SDate=None
------>update_bywho=None
------>publish_year=2008
------>submit_flag=None
------>publish_month=6
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z