Fukushima T, Lee JA, Korenaga T, Ichihara H, Kato M, Imai K |
------>authors3_c=None ------>paper_class1=1 ------>Impact_Factor=None ------>paper_class3=2 ------>paper_class2=1 ------>vol=15 ------>confirm_bywho=kyhsu ------>insert_bywho=jenai ------>Jurnal_Rank=None ------>authors4_c=None ------>comm_author= ------>patent_EDate=None ------>authors5_c=None ------>publish_day=None ------>paper_class2Letter=None ------>page2=180 ------>medlineContent= ------>unit=G0100 ------>insert_date=20010725 ------>iam=2 ------>update_date= ------>author=??? ------>change_event=5 ------>ISSN=None ------>authors_c=None ------>score=500 ------>journal_name=Biomedical Chromatography ------>paper_name=Simultaneous determination of D-lactic acid and 3-hydroxybutyric acid in rat plasma using a column-switching HPLC with fluorescent derivatization with 4-nitro-7-piperazino-2,1,3-benzoxadiazole (NBD-PZ) ------>confirm_date=20020321 ------>tch_id=089023 ------>pmid=11391675 ------>page1=173 ------>fullAbstract=A highly sensitive method for the determination of D-lactic acid and 3-hydroxybutyric acid (3-HB) in rat plasma was developed using high-performance liquid chromatography with octadecylsilica (ODS) connected to a chiral column. At first, (D + L)-lactic acid and 3-HB in the plasma were derivatized with a fluorescent reagent, 4-nitro-7-piperazino-2,1,3-benzoxadiazole (NBD-PZ), separated on the ODS column and determined fluorimetrically at 547 nm with 491 nm of excitation wavelength. During the separation step on the ODS, the peak fraction of (D + L)-lactate derivative was introduced directly to a phenylcarbamoylated beta-cyclodextrin chiral column by changing the flow of the eluent via a six-port valve. Then, D-lactate derivative was separated enantiomerically from the L-lactate derivative, and the enantiomeric ratio was determined from the chromatogram. Intra- and inter-day accuracy values for the determination of D-lactic acid in 10 microL of rat plasma were 97.8-109.2 and 98.4-109.9%, and those for 3-HB were 99.8-108.4 and 99.8-103.8%, respectively. The intra- and inter-day precision values were within 4.6 and 5.1% for D-lactic acid, and 2.7 and 2.4% for 3-HB, respectively. The detection limits for D-lactic acid and 3-HB were approximately 2.0 and 0.04 microM, respectively (signal-to-noise ratio 3). The proposed method was applied to the plasma of diabetic rats induced by intraperitoneal administration of streptozotocin, and the significant increases of both D-lactic acid and 3-HB concentrations were observed in the diabetic rats as compared to the normal rats. ------>tmu_sno=None ------>sno=4015 ------>authors2=None ------>authors3=None ------>authors4=None ------>authors5=None ------>authors6=None ------>authors6_c=None ------>authors=Fukushima T, Lee JA, Korenaga T, Ichihara H, Kato M, Imai K ------>delete_flag=0 ------>SCI_JNo=None ------>authors2_c=None ------>publish_area=None ------>updateTitle=Simultaneous determination of D-lactic acid and 3-hydroxybutyric acid in rat plasma using a column-switching HPLC with fluorescent derivatization with 4-nitro-7-piperazino-2,1,3-benzoxadiazole (NBD-PZ). ------>language=2 ------>check_flag= ------>submit_date= ------>country=None ------>no=3 ------>patent_SDate=None ------>update_bywho= ------>publish_year=2001 ------>submit_flag= ------>publish_month=None |