Taipei Medical University

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Fukushima T, Lee JA, Korenaga T, Ichihara H, Kato M, Imai K
------>authors3_c=None
------>paper_class1=1
------>Impact_Factor=None
------>paper_class3=2
------>paper_class2=1
------>vol=15
------>confirm_bywho=kyhsu
------>insert_bywho=jenai
------>Jurnal_Rank=None
------>authors4_c=None
------>comm_author=
------>patent_EDate=None
------>authors5_c=None
------>publish_day=None
------>paper_class2Letter=None
------>page2=180
------>medlineContent=
------>unit=G0100
------>insert_date=20010725
------>iam=2
------>update_date=
------>author=???
------>change_event=5
------>ISSN=None
------>authors_c=None
------>score=500
------>journal_name=Biomedical Chromatography
------>paper_name=Simultaneous determination of D-lactic acid and 3-hydroxybutyric acid in rat plasma using a column-switching HPLC with fluorescent derivatization with 4-nitro-7-piperazino-2,1,3-benzoxadiazole (NBD-PZ)
------>confirm_date=20020321
------>tch_id=089023
------>pmid=11391675
------>page1=173
------>fullAbstract=A highly sensitive method for the determination of D-lactic acid and 3-hydroxybutyric acid (3-HB) in rat plasma was developed using high-performance liquid chromatography with octadecylsilica (ODS) connected to a chiral column. At first, (D + L)-lactic acid and 3-HB in the plasma were derivatized with a fluorescent reagent, 4-nitro-7-piperazino-2,1,3-benzoxadiazole (NBD-PZ), separated on the ODS column and determined fluorimetrically at 547 nm with 491 nm of excitation wavelength. During the separation step on the ODS, the peak fraction of (D + L)-lactate derivative was introduced directly to a phenylcarbamoylated beta-cyclodextrin chiral column by changing the flow of the eluent via a six-port valve. Then, D-lactate derivative was separated enantiomerically from the L-lactate derivative, and the enantiomeric ratio was determined from the chromatogram. Intra- and inter-day accuracy values for the determination of D-lactic acid in 10 microL of rat plasma were 97.8-109.2 and 98.4-109.9%, and those for 3-HB were 99.8-108.4 and 99.8-103.8%, respectively. The intra- and inter-day precision values were within 4.6 and 5.1% for D-lactic acid, and 2.7 and 2.4% for 3-HB, respectively. The detection limits for D-lactic acid and 3-HB were approximately 2.0 and 0.04 microM, respectively (signal-to-noise ratio 3). The proposed method was applied to the plasma of diabetic rats induced by intraperitoneal administration of streptozotocin, and the significant increases of both D-lactic acid and 3-HB concentrations were observed in the diabetic rats as compared to the normal rats.
------>tmu_sno=None
------>sno=4015
------>authors2=None
------>authors3=None
------>authors4=None
------>authors5=None
------>authors6=None
------>authors6_c=None
------>authors=Fukushima T, Lee JA, Korenaga T, Ichihara H, Kato M, Imai K
------>delete_flag=0
------>SCI_JNo=None
------>authors2_c=None
------>publish_area=None
------>updateTitle=Simultaneous determination of D-lactic acid and 3-hydroxybutyric acid in rat plasma using a column-switching HPLC with fluorescent derivatization with 4-nitro-7-piperazino-2,1,3-benzoxadiazole (NBD-PZ).
------>language=2
------>check_flag=
------>submit_date=
------>country=None
------>no=3
------>patent_SDate=None
------>update_bywho=
------>publish_year=2001
------>submit_flag=
------>publish_month=None
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z